If your project is by the sea on water or downwind of heavy industry ask for a salt mist report. It depicts the performance of a module’s frame coatings and electrical parts in a controlled corrosion test that a datasheet claim cannot substitute. Solar panel test services can run that test but a buyer also needs to know what edition of the standard and what test method applies to the site. This post explains how to choose and what to look for in the report
If your project is by the sea on water or downwind of heavy industry ask for a salt mist report. It depicts the performance of a module’s frame coatings and electrical parts in a controlled corrosion test that a datasheet claim cannot substitute. Solar panel test services can run that test but a buyer also needs to know what edition of the standard and what test method applies to the site. This post explains how to choose and what to look for in the report.
Why Salt and Ammonia Attack Modules Faster Than Sunlight
Sunlight slowly ages a module Salt is quicker. Salt-laden moisture deposits on frames connectors and junction boxes and can, over time, corrode metal parts and degrade coatings and plastics. The weak points of the modules of coastal solar plants are often not the glass, but the metalwork and electrical connections.
Salt and ammonia pose different risks. Salt mist testing under IEC 61701 assesses resistance to saline environments, while ammonia testing is covered by the separate standard IEC 62716. A salt mist report does not confirm resistance to ammonia or other industrial fumes. A solar panel testing laboratory in India can help buyers identify the relevant test requirements for their site's environmental conditions.
How the IEC 61701 Test Works
In a salt mist corrosion test, modules are exposed to a controlled salty atmosphere and then examined for changes. The samples are measured, exposed to a salt mist, washed and allowed to recover, measured again and a bypass diode check is performed where the module has diodes in the 2020 edition. A control sample is kept aside to separate the effect of the exposure from normal variation.
The salt mist corrosion test includes checks such as visual inspection, maximum power, insulation, wet leakage current and earth-bonding continuity. The standard requires that corrosion or mechanical damage must not materially impair the module's function. It also refers to IEC 61215 and IEC 61730 for relevant pass criteria.
Which edition of IS/IEC 61701 reference in your tender for testing? The 2020 edition replaced the 2011 edition. The salt spray test solar panel makers quote can be different between them. Here, no timeframes are given, as they depend on the chosen test method.
Severity Levels and Which One Fits a Coastal or Industrial Site
In the 2011 edition, IEC 61701 uses the term “severity level,” and a test certificate may identify a level, such as “Severity 6.” However, the approach changed in the 2020 edition. It refers to test methods from IEC 60068-2-52 and provides guidance in an annex related to ISO 9223 corrosivity classes. Methods 2 and 3 are excluded. Therefore, when arranging solar panel test services, first confirm which edition the buyer or tender refers to before selecting a test level.
Think about sea spray and salt deposits, distance from the water and direction of the wind. Coastal rooftop, offshore and floating projects are in different states even within one region so a project in Gujarat, Tamil Nadu or Odisha can’t be compared to a level just on the basis of location.
Other corrosive materials can contaminate industrial air and salt isn’t always the culprit. Determine what is in the air before you specify a test.
For both editions, the site environment, tender conditions and manufacturer guidance help determine the appropriate test requirements. A higher severity level does not guarantee a fixed service life. The project team is responsible for setting the specifications, while solar panel test services can help buyers identify the relevant testing requirements and align them with the site conditions. A solar panel testing laboratory in India can also clarify the applicable test method and standard edition.
What Fails: Frames, Junction Boxes, Connectors and Cell Interconnects
Corrosion can affect metal frames, protective coatings, junction boxes, connectors and connections between cells. It may cause resistance, leakage current or loss of power. That’s not true in all modules and that’s where the report comes in.
Upon receipt of a PV module corrosion test report, verify the model that was tested the method and duration of the test the salt solution, the before and after measurements and any observations. The standard calls for these details and a vague "corrosion resistant" claim in the absence of them tells you little. A solar module durability test is meaningless without a description of the conditions. Similar documentation checks are also important in Electronics & IT testing services, where reports must clearly identify the product and relevant test requirements.
Where Salt Mist Sits Next to IS 14286 and ALMM Requirements
These are three separate things. IS 14286, PV module qualification, is generally based on IEC series 61215. ALMM is the list of module models and manufacturers approved by MNRE with its own eligibility criteria. Another corrosion test is IEC 61701.
Depending on the applicable rules and site conditions salt mist testing may be required by a tender or project specification. In India it is not automatically mandatory for every module. A salt mist report does not establish compliance with IS 14286 or confirm ALMM listing. Similarly Household Appliances Testing Services follow their own applicable product standards and testing requirements.
Why Choose ACE Test Labs?
ACE Test Labs & Metrology Pvt. Ltd. is a testing laboratory based in Sonipat, Haryana. Our lab lists IS/IEC 61701 in its testing scope. As a NABL testing lab, we recommend checking the current accreditation scope to confirm whether it covers your specific test requirements.
Before booking, discuss your module type required test method or severity level, standard edition and documentation needs with our team. If you are looking for solar panel test services contact ACE to discuss your requirements. As a BIS testing company, we also recommend confirming that the applicable standard and required reports match your project or tender conditions.